Customization: | Available |
---|---|
Voltage Type: | DC Voltage |
Measuring Principle: | Hall Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model |
LR-W70C |
|||
Type |
Small/Dual Spot Type |
|||
Detecting distance |
30 to 70 mm 1.18" to 2.76" |
|||
Min. spot diameter |
Approx. 1.6 x 2.9mm at 50 mm 0.06" × 0.11" at 1.97" |
|||
Light source |
White LED |
|||
Mutual interference reduction function |
Up to 2 units when alternate frequencies set |
|||
Timer |
OFF/ON delay/OFF delay/One-shot |
|||
Response time |
1-Spot Mode: 200 µs, 1 ms, 10 ms, 100 ms, 500 ms selectable |
|||
I/O |
Control output |
NPN open collector/PNP open collector selectable |
||
External input |
Tuning /Transmission OFF selectable |
|||
Protection circuit |
Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection |
|||
Power supply |
Power voltage |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Current consumption |
60 mA or less (without load) at 24 VDC; |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less |
|||
Ambient temperature |
-20 to +50 °C -4 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: Zinc die cast (Nickel chrome plating), |
|||
Weight |
Approx. 75 g |